Absolute Pro™ Vascular
Self-expanding Stent System


 

Precision. Performance. Results.

Excellent precision, flexibility, and proven clinical resultsin the iliacs.

Precision

  • Tri-axial technology to ensure precise stent placement

Performance

  • Flexible nitinol material
  • 12 radiopaque nitinol markers (6 on each end) for visibility

Clinical Results

  • 98.9% clinically driven freedom from TLR at 9 months
  • 92.1% primary patency at 2 years in iliacs1
  • 84.8% primary patency in TASC D lesions at 2 years in iliacs*1

High Freedom from Clinically Driven TLR through 3 years

Significant Sustained Improvement in Walking Capacity

Tri-Axial Technology Specifications

Stent Size Matrix

Ordering Information

Absolute Pro Vascular Self-Expanding Stent System
Stock Number
Catheter Length
Diameter (mm)Length (mm)Sheath Compatibility
80 (cm)135 (cm)
1011914-0201011920-0205.0206
1011914-0301011920-0305.0306
1011914-0401011920-0405.0406
1011914-0601011920-0605.0606
1011914-0801011920-0805.0806
1011914-1001011920-1005.01006
1011915-0201011921-0206.0206
1011915-0301011921-0306.0306
1011915-0401011921-0406.0406
1011915-0601011921-0606.0606
1011915-0801011921-0806.0806
1011915-1001011921-1006.01006
1011916-0201011922-0202.5206
1011916-0301011922-0302.5306
1011916-0401011922-0407.0406
1011916-0601011922-0607.0606
1011916-0801011922-0807.0806
1011916-1001011922-1007.01006
1011917-0201011923-0208.0206
1011917-0301011923-0308.0306
1011917-0401011923-0408.0406
1011917-0601011923-0608.0606
1011917-0801011923-0808.0806
1011917-1001011923-1008.01006
1011918-0201011924-0209.0206
1011918-0301011924-0309.0306
1011918-0401011924-0409.0406
1011918-0601011924-0609.0606
1011918-0801011924-0809.0806
1011918-1001011924-1009.01006
1011919-0201011925-02010.0206
1011919-0301011925-03010.0306
1011919-0401011925-04010.0406
1011919-0601011925-06010.0606
1011919-0801011925-08010.0806
1011919-1001011925-10010.01006
Absolute Pro LL Vascular Self-Expanding Stent System
Stock Number
Catheter Length
Diameter (mm)Length (mm)Sheath Compatibility
80 (cm)135 (cm)
1012008-1201012014-1205.01206
1012008-1501012014-1505.01506
1012009-1201012015-1206.01206
1012009-1501012015-1506.01506
1012010-1201012016-1207.01206
1012010-1501012016-1507.01506
1012011-1201012017-1208.01206
1012011-1501012017-1508.01506

Compatible with 0.035" guide wire only - use of an undersized guide wire with insufficient support may cause kinking in the stent delivery system.**


 

Discover Abbott’s Peripheral intervention technology


 

Abbott’s Peripheral Intervention Portfolio

Data on file at Abbott.

*Combined clinical results from BRAVISSIMO study where 54%/46% of TASC D lesions were treated with Absolute Pro™ Vascular Self-Expanding Stent System / Omnilink Elite™ Vascular Balloon-Expandable Stent System respectively.
**Absolute Pro™ .035 Self-Expanding Stent System and Absolute Pro™ LL Self-Expanding Stent System Instructions For Use (IFU).
Refer to IFU for additional information.


References

  1. Donato, G. et al. 24-Month Data from the BRAVISSIMO: A Large-Scale Prospective Registry on Iliac Stenting for TASC A & B and TASC C & D Lesions. Annals of Vascular Surgery. 2015; 29(4): 738-750.

 

MAT-2117132 V1.0