Maximize Therapy Impact

Gallant™ ICD and CRT-D Devices

Gallant ICDs and CRT-Ds

Available in all device configurations to improve quality of life for patients at every stage of therapy.

Abbott Implantable Cardioverter Defibrillators (ICDs) and Cardiac Resynchronization Therapy Defibrillators (CRT-Ds) are built with exclusive algorithms proven to deliver better patient outcomes. It is this type of innovation that drives us at Abbott to personalize therapy and restore quality of life for patients. 

Options to Achieve the Narrowest QRS for Improved Response.1

 

 

SyncAV™ CRT technology provides the most QRS narrowing options at implant for patients. QRS narrowing after CRT implantation allows improved mortality. In patients with LBBB, QRS narrowing after CRT implant is associated with 2x lower mortality.2

24% narrower QRS

Potential to Save More Lives with Therapy Assurance.

VF Therapy Assurance is the only technology to provide an additional safety net for difficult-to-detect ventricular arrhythmias. Without VF Therapy Assurance, ventricular tachyarrhythmias with low and varying signal amplitudes may not be successfully identified.3,4

of patients who received HV therapy due to VF Therapy Assurance's enhanced detection would have been otherwise untreated for potentially life-threatening arrhythmias.

86% of patients

Protect Patients with a Physiologic Waveform.
No DFT Test Needed.

 

 

DeFT Response™ technology is the industry’s most flexible option for the management of high defibrillation thresholds. The algorithm supports a 10J shock safety margin for patients.5

24% narrower QRS

Real-World Clinical Evidence

41% reduction in heart
failure readmissions6

41%

34% reduction in all-cause
hospitalization readmissions6

34%

23% reduction ($1,135)
in 2-year cost6

23%

 

$4,031

lifetime savings per
CRT patient6

 

Why Do We Implant Defibrillators?
Because every patient deserves life-saving therapy.

Abbott's ICD and CRT-D platforms are designed with patient outcomes in mind. Rob, a Navy veteran, experienced a cardiac arrest that required five shocks on the way to the hospital. With a Gallant™ ICD implant, Rob and his family now feel confident he's receiving the life-saving therapy he needs.

Enabling Safe MRI Scans

MRI icon

With Abbott-exclusive No Wait 1.5T and 3T MRI, ensure your patients can get the scans they need, when they need it.*

Abbott's MRI-ready solutions ensure no loss of CRT therapy for your patients in full-body scans and allows for MRI Timeout programming.**

Stay Informed

Sign up to hear about our technology, education opportunities, and more.

Read the Latest Blog Article

Stay up to date with recent news, product highlights, and case studies.

References

  1. Varma N, O’Donnell D, Bassiouny M, et al. Programming cardiac resynchronization therapy for electrical synchrony: reaching beyond left bundle branch block and left ventricular activation delay. J Am Heart Assoc. 2018;7:e007489. http://jaha. ahajournals.org/content/ 7/3/e007489. Accessed June 29, 2018.
  2. Jastrzebski M, Baranchuk A, Fijorek K, et al. Cardiac resynchronization therapy-induced acute shortening of QRS duration predicts long-term mortality only in patients with left bundle branch block. Europace. 2019 Feb 1;21(2):281-289. doi: 10.1093/europace/euy254. PMID: 30403774.
  3. Wilkoff BL, Sterns LD, Katcher MS, et al. Novel Ventricular Tachyarrhythmia Detection Enhancement Detects Undertreated Life- Threatening Arrhythmias. Heart Rhythm 02. 2021 Nov 18;3(1):70-78. doi: 10.1016/j.hroo.2021.11.0092 021.
  4. Stroobandt RX, Duytschaever MF, Strisciuglio T, et al Failure to detect life-threatening arrhythmias in ICDs using single-chamber detection criteria. Pacing Clin Electrophysiology. 2019;42:583-594. DOI:10.1111/pace.13610.3
  5. Gabriels J, Budzikowski AS, Kassotis JT. Defibrillation waveform duration adjustment increases the proportion of acceptable defibrillation thresholds in patients implanted with single-coil defibrillation leads. Cardiology. 2013;124(2):71-75.
  6. Varma N, Hu Y, Connolly AT, Thibault B, Singh B, Mont L, Nabutovsky Y, Zareba W. Gain in real-world cardiac resynchronization therapy efficacy with SyncAV dynamic optimization: Heart failure hospitalizations and costs. Heart Rhythm. 2021 Sep;18(9):1577-1585.  doi: 10.1016/j.hrthm.2021.05.006. Epub 2021 May 7. PMID: 33965608.

Gallant™/Entrant™ ICDs and CRT-Ds  

Rx Only

Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

Intended Use: The Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy Defibrillator (CRT-D) devices are primarily intended for use with compatible leads detect and treat life threatening ventricular arrhythmias by providing ventricular antitachycardia pacing and ventricular cardioversion/defibrillation. In addition, these devices can detect and treat: chronic symptomatic bradyarrhythmia by providing sensing and pacing in the right ventricle; various atrioventricular conduction abnormalities by providing sensing and pacing in the right ventricle and/or right atrium. CRT-D devices sense cardiac activity and provide pacing to resynchronize the right and left ventricles.  

The myMerlinPulse™ mobile application is intended for use by people who have an Abbott Medical implanted heart device and access to a mobile device. The app provides remote monitoring capability of the implanted heart device by transmitting information from the patient’s implanted heart device to the patient’s healthcare provider.

Indications: The ICD devices are indicated in patients who have already survived a cardiac arrest or are at a high risk of Sudden Cardiac Death (SCD) due to VT (ventricular tachycardia) or VF (ventricular fibrillation). Cardiac Resynchronization Therapy (CRT) devices are indicated for reduction of symptoms in patients who have congestive heart failure, a reduced left ventricular ejection fraction (LVEF) and a prolonged QRS duration. CRT-D devices are indicated in patients who meet the CRT indications and have already survived a cardiac arrest or are at a high risk of Sudden Cardiac Death (SCD) due to VT (ventricular tachycardia) or VF (ventricular fibrillation). The device is most commonly implanted within a device pocket in the pectoral region. 

The myMerlinPulse™ mobile application is indicated for use by patients with supported Abbott Medical implanted heart devices.

Contraindications: Contraindications for use of the pulse generator system include ventricular tachyarrhythmias resulting from transient or correctable factors such as drug toxicity, electrolyte imbalance, or acute myocardial infarction. 

The myMerlinPulse™ mobile application is contraindicated for use with any implanted medical device other than supported Abbott Medical implanted heart devices.

Adverse Events: Possible adverse events associated with the implantation of the pulse generator system include the following: Arrhythmia (for example, accelerated or induced), Bradycardia, Cardiac or venous perforation, Cardiac tamponade, Cardiogenic shock, Death, Discomfort, Embolism, Endocarditis, Erosion, Exacerbation of heart failure, Excessive fibrotic tissue growth, Extracardiac stimulation (phrenic nerve, diaphragm, pectoral muscle), Extrusion, Fluid accumulation within the device pocket, Formation of hematomas, cysts, or seromas, Heart block, Hemorrhage, Hemothorax, Hypersensitivity, including local tissue reaction or allergic reaction, Infection, Keloid formation, Myocardial damage, Nerve damage, Occlusion/Thrombus, Pericardial effusion, Pericarditis, Pneumothorax, Pulmonary edema, Syncope, Thrombosis, Valve damage. Complications reported with direct subclavian venipuncture include pneumothorax, hemothorax, laceration of the subclavian artery, arteriovenous fistula, neural damage, thoracic duct injury, cannulation of other vessels, massive hemorrhage and rarely, death. Among the psychological effects of device implantation are imagined pulsing, depression, dependency, fear of premature battery depletion, device malfunction, inappropriate pulsing, shocking while conscious, or losing pulse capability. Possible adverse device effects include complications due to the following: Abnormal battery depletion, Conductor fracture, Device-programmer communication failure, Elevated or rise in defibrillation/cardioversion threshold, Inability to defibrillate or pace, Inability to interrogate or program due to programmer or device malfunction, Incomplete lead connection with pulse generator, Inhibited therapy including defibrillation and pacing, Inappropriate therapy (for example, shocks and antitachycardia pacing [ATP] where applicable, pacing), Interruption of function due to electrical or magnetic interference, Intolerance to high rate pacing (for example dyspnea or discomfort), Lead abrasion, Lead fracture, Lead insulation damage, Lead migration or lead dislodgement, Loss of device functionality due to component failure, Pulse generator migration, Rise in DFT threshold, Rise in pacing threshold and exit block, Shunting of energy from defibrillation paddles, System failure due to ionizing radiation. Additionally, potential adverse events associated with the implantation of a coronary venous lead system include the following: Allergic reaction to contrast media, Breakage or failure of implant instruments, Prolonged exposure to fluoroscopic radiation, Renal failure from contrast media used to visualize coronary veins.  

No potential adverse events have been identified with use of the myMerlinPulse™ mobile application.

 Competition defined as LV Only and BiV Simultaneous pacing modes. Modes 1 and IV of the referenced JAHA data. Numbers were rounded up for graphic representation.

§ Fixed-tilt group of patients with competitive devices only achieved 83% success for maintaining a 10J safety margin.

* For additional information about specific MR Conditional ICDs and leads, including scan parameters, warnings, precautions, adverse conditions to MRI scanning, and potential adverse events, please refer to the Abbott MRI-Ready Systems Manual at manuals.eifu.abbott.

** No Loss of CRT therapy only applicable for model numbers CDHFA500Q, CDHFA500T, CDHFA500D, CDHFA500B.