Epic™ Platform

Stented Tissue Valves

Epic™ Platform valve illustration

Opening a Lifetime of Possibilities

For decades, Epic™ has been the surgical valve platform that cardiac surgeons and patients have relied on for more. More flexibility. More possibilities.

The Epic Platform includes the Epic Max aortic valve and the Epic Plus portfolio of valves.

The Epic Platform delivers everything you’ve come to expect from Epic— excellent hemodynamics, implantability to enable implantation for even the most challenging patient anatomies, proven long-term durability, and features designed for future intervention.

With the Epic Platform you and your patients can continue to depend on Epic valves for more — both now and in the future. Reliable therapy for today, tomorrow, and the road ahead.

 

Learn about the features of the Epic Max valve and the Epic Plus Valves.

Epic Max surgical valve
Epic Plus  Supra
Epic Plus surgical valve

Learn more about the Epic Platform by visiting the Abbott Structural Heart website

Ordering Information

Epic™ Max Aortic Stented Tissue Valve
Model NumberValve Size (mm)Tissue Annulus Diameter (mm)Internal Diameter1 (Stent ID mm)Aortic Protrusion (mm)Total Height (mm)Cuff Diameter (mm)
EMAX-19191920.8111527.5
EMAX-21212122.6131629.0
EMAX-23232324.5131731.0
EMAX-25252526.3141933.0
EMAX-27*272728.4152035.5

1 Stent Internal Diameter does not account for the tissue/fabric covering the stent which may vary in thickness between approximately 1 to 2 mm.
*This size may not be available in your region

 

Epic™ Plus Supra Aortic Stented Tissue Valve
Model NumberValve Size (mm)Tissue Annulus Diameter (mm)Internal Diameter1 (Stent ID mm)Aortic Protrusion (mm)Total Height (mm)Cuff Outer Diameter (mm)
ESP200-19191918.7111425
ESP200-21212120.8111528
ESP200-23232322.6131629
ESP200-25252524.5131731
ESP200-27272726.3141933
ESP200-29*292928.4152035

1 Stent Internal Diameter does not account for the tissue/fabric covering the stent which may vary in thickness between approximately 1 to 2 mm.
*This size may not be available in your region

 

Epic™ Plus Aortic Stented Tissue Valve
Model NumberValve Size (mm)Tissue Annulus Diameter (mm)Internal Diameter1 (Stent ID mm)Aortic Protrusion (mm)Total Height (mm)Cuff Diameter (mm)
E200-21A212118.791425
E200-23A232320.891527
E200-25A252522.6101629
E200-27A272724.5111731
E200-29A292926.3121933

1 Stent Internal Diameter does not account for the tissue/fabric covering the stent which may vary in thickness between approximately 1 to 2 mm.
 

Epic™ Plus Mitral Stented Tissue Valve
Model NumberValve Size (mm)Tissue Annulus Diameter (mm)Internal Diameter1 (Stent ID mm)Ventricular Protrusion (mm)Total Height (mm)Cuff Outer Diameter (mm)
E200-25M252522.691633
E200-27M272724.591735
E200-29M292926.3101937
E200-31M313128.4102039
E200-33M333330.3112041

1 Stent Internal Diameter does not account for the tissue/fabric covering the stent which may vary in thickness between approximately 1 to 2 mm.
 

Accessories

Model NumberDescription
EMAX-1000Epic™ Max Heart Valve Sizer Set
One (1) click -in aortic series holder handle
Five (5) double ended aortic sizers (19, 21, 23, 25, 27 mm)
E2000Epic™ Plus Heart Valve Sizer Set
One (1) click-in Aortic holder handle
One (1) Screw-in holder handle
Six (6) double-ended aortic/Supra sizers (19, 21, 23, 25, 27, 29)
Five (5) mitral sizers (25, 27, 29, 31, 33)
One (1) autoclavable tray for storage of components
One (1) autoclavable tray cover
E2000-HAReplacement handle
One (1) click-in Aortic holder handle
E2000 HMReplacement handle
One (1) Screw-in Mitral holder handle

Important Safety Information

  EPICTM MAX STENTED PORCINE TISSUE VALVES

rx-only-logo

Indications for Use 

The Epic™ Max valve is indicated for patients requiring replacement of a diseased, damaged, or malfunctioning native aortic heart valve. It may also be used as a replacement for a previously implanted aortic prosthetic heart valve. 

 

Contraindications

None known. 

 

Potential Adverse Events

Adverse events potentially associated with the use of bioprosthetic heart valves (in alphabetical order) include: angina; cardiac arrhythmias; endocarditis; heart failure; hemolysis; hemolytic anemia; hemorrhage, anticoagulant/antiplatelet-related; leak, transvalvular or paravalvular; myocardial infarction; nonstructural dysfunction (entrapment by pannus or suture, inappropriate sizing or positioning, or other); prosthesis regurgitation; stroke; structural deterioration (calcification, leaflet tear, or other); thromboembolism; valve thrombosis. It is possible that these complications could lead to: reoperation; explantation; permanent disability; death. 

 

  EPIC™ PLUS/ EPIC™ PLUS SUPRA STENTED PORCINE TISSUE VALVES

rx-only-logo

Indications for Use

The Epic™ Plus valve is indicated for patients requiring replacement of a diseased, damaged, or malfunctioning native aortic and/or mitral heart valve. It may also be used as a replacement for a previously implanted aortic and/or mitral prosthetic heart valve.

The Epic™ Plus Supra valve is indicated for patients requiring replacement of a diseased, damaged, or malfunctioning native aortic heart valve. It may also be used as a replacement for a previously implanted aortic prosthetic heart valve.

Contraindications

None known.

Potential Adverse Events

Adverse events potentially associated with the use of bioprosthetic heart valves (in alphabetical order) include: angina; cardiac arrhythmias; endocarditis; heart failure; hemolysis; hemolytic anemia; hemorrhage, anticoagulant/antiplatelet-related; leak, transvalvular or paravalvular; myocardial infarction; nonstructural dysfunction (entrapment by pannus or suture, inappropriate sizing or positioning, or other); prosthesis regurgitation; stroke; structural deterioration (calcification, leaflet tear, or other); thromboembolism; valve thrombosis.

 

It is possible that these complications could lead to: reoperation; explantation; permanent disability;

death.

MAT-2307791 v1.0