A - Vascular Plug Diameter
B - Unconstrained Length
Device Dimensions | Vessel Size | |||
---|---|---|---|---|
Model/ Reorder Number | Vascular Plug Diameter [A] | Unconstrained Length [B] | Product Description* | Treatable Vessel Diameter Range† |
9-AVP2-003 | 3 mm | 6 mm | AVP II - 3mm x 6mm | 2.0 mm-2.5 mm |
9-AVP2-004 | 4 mm | 6 mm | AVP II - 4mm x 6mm | 2.5 mm-3.0 mm |
9-AVP2-006 | 6 mm | 6 mm | AVP II - 6mm x 6mm | 4.0 mm-4.5 mm |
9-AVP2-008 | 8 mm | 7 mm | AVP II - 8mm x 7mm | 5.5 mm-6.0 mm |
9-AVP2-010 | 10 mm | 7 mm | AVP II - 10mm x 7mm | 6.5 mm-7.5 mm |
9-AVP2-012 | 12 mm | 9 mm | AVP II - 12mm x 9mm | 8.0 mm-9.0 mm |
9-AVP2-014 | 14 mm | 10 mm | AVP II - 14mm x 10mm | 9.5 mm-11.0 mm |
9-AVP2-016 | 16 mm | 12 mm | AVP II - 16mm x 12mm | 10.5 mm-12.5 mm |
9-AVP2-018 | 18 mm | 14 mm | AVP II - 18mm x 14mm | 12.0 mm-14.0 mm |
9-AVP2-020 | 20 mm | 16 mm | AVP II - 20mm x 16mm | 13.5 mm-15.5 mm |
9-AVP2-022 | 22 mm | 18 mm | AVP II - 22mm x 18mm | 14.5 mm-17.0 mm |
†Treatable vessel diameter range based on the devices Instructions for Use to select a plug that is oversized by approximately 30-50% at the occlusion site.
*Each Amplatzer™ Vascular Plug II comes pre-loaded on a 135cm nitinol delivery wire.
MAT-2002814 v1.0
Intended Use: The AMPLATZER™ Vascular Plug II is indicated for arterial and venous embolizations in the peripheral vasculature.
Contraindications: None known.
Warnings: The safety and effectiveness of this device for cardiac uses (for example, patent ductus arteriosus or paravalvular leak closures) and neurological uses have not been established.
Precautions:
MRI Safety Information:
A patient with the Amplatzer™ Vascular Plug II may be safely scanned under the following conditions. Failure to follow these conditions may result in injury to the patient. | |
Device Name | Amplatzer™ Vascular Plug II |
Static Magnetic Field Strength (B0) | 1.5 T or 3.0 T |
Maximum Field Spatial Gradient | 19T/m (1900 gauss/cm) |
RF Excitation | Circularly Polarized (CP) |
RF Transmit Coil Type | Body Coil |
Operating Mode | Normal Operating Mode |
Maximum Whole Body SAR | 2.0W/kg (Normal Operating Mode) |
Maximum Head SAR | N/A |
Scan Duration | 2.0W/kg whole-body-averaged SAR for 15 minutes of continuous scanning |
MR Image Artifact | The presence of this implant may produce an image artifact. |